EasyManua.ls Logo

Fujitsu PRIMERGY TX1320 M5

Fujitsu PRIMERGY TX1320 M5
407 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Preliminary steps
If the HDD to be removed is combined into a RAID array, proceed as
follows:
RAID level Procedure
RAID 0
CAUTION
RAID 0 provides no data redundancy.
In case of an HDD/SSD module is defect,
all data are lost!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID
5 array will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or
larger capacity
.
After replacing the HDD module, RAID
rebuild will be performed as a background
process, see "Performing a RAID array
rebuild" on page 92.
In order to permanently remove an operational HDD that is part of a RAID
array from the server
, you first need to delete the array using ServerV
iew RAID
Manager.
CAUTION
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array!
Be sure to back up your data before deleting a RAID array.
For more information, see the "ServerView Suite RAID
Management" user guide.
"Shutting down the server" on page 45
.
"Getting access to the component" on page 48.
Hard disk drive (HDD) / solid state drive (SSD)
144 Upgrade and Maintenance Manual TX1320 M5