●Callpage7bypushingtheS1button6timesfrom
the[SENSOR]menu.
SENSOR : RELOAD
SENSOR : REGISTER
This page is set when using multiple telemetry sensors of the same type.
This page is set when using multiple telemetry sensors of the same type.
When using multiple sensors of the same type
the sensors must be registered in the transmitter.
Connect all the sensors to be used to the T12K as
shown in the gure at the right and register them by
the following procedure. The ID of each sensor is
registered in the transmitter.
This function registers an additional sensor.
Connect the sensor as shown in the figure at the
right and register it by the following procedure.
The sensor ID is registered in the transmitter.
All the sensors to be used are connected.
SENSOR
SENSOR
3-way hub
or Y-harnesses
Receiver's
battery
SENSOR
SENSOR
SENSOR
3-way hub
or Y-harnesses
Receivers
battery
SENSOR
Reading all the sensors to be used
1.Connectallthesensorsandreceiver
batteriestobeusedtotheT12Kthrougha
hubasshowninthegureabove.
2.Movethecursorto“RELOAD”onpage7of
the[SENSOR]screen.
3.PushtheRTNbutton.
Allthesensorsareregisteredandcanbe
used.
Additional sensor registration
1.Connectthesensorandreceiverbatteryto
beusedtotheT12Kthroughahubasshown
inthegureattheright.
2.Movethecursorto“REGISTER”onpage7of
the<Sensor>screen.
3.PushtheRTNbutton.
Thesensorisregisteredandcanbeused.
*
When the number of slots needed in registration is
insufcient, an error is displayed and registration cannot be
performed. Disable unused slots or perform the following
relocate.