END POINT
Setsthetravelandlimitpointofeachservo.
The End Point function adjusts the left and right
servo throws, generates differential throws, and
will correct improper linkage settings.
The travel rate can be varied from 0% to 140%
in each direction on channels 1 to 12 (T-FHSS Air).
Also, the limit point where servo throw stops may
be varied from 0% to 155%.
Servo travel adjustment
1.Movethecursortothetraveliconofthe
channelyouwanttoadjustandpushthe
RTNbuttontoswitchtothedatainputmode.
2.AdjusttheratebyscrollingthePushdial.
Initialvalue:100%
Adjustmentrange:0%~140%
*When the RTN button is pushed for one second, the rate is
reset to the initial value.
PushtheRTNbuttontoendadjustmentand
returntothecursormode.
3.Repeatthisprocedureforeachrate.
Limit point adjustment
1.Movethecursortothelimitpointiconofthe
channelyouwanttoadjustandpushthe
RTNbuttontoswitchtothedatainputmode.
2.AdjustthelimitpointbyscrollingthePush
dial.
Initialvalue:135%
Adjustmentrange:0%~155%
*When the RTN button is pushed for one second, the limit
point is reset to the initial value.
PushtheRTNbuttontoendadjustmentand
returntothecursormode.
3.Repeatthisprocedureforeachlimitpoint.
●Select[ENDPOINT]intheLinkagemenuand
accessthesetupscreenshownbelowbypushing
theRTNbutton.
(The display screen is an example. The
screen depends on the model type.)
(limitpoint)
(travel)
(limitpoint)
(travel)
Scrolling
●Movingcursor
●Selectingmode
●Adjustingvalue
●Tonextpage
●Toinputdatamode
●Dataisentered