GYRO
[Correspondingmodeltype]:Airplane/glider/Multirotor,general
This function is used when a GYA Series gyro
is used to stabilize the aircraft's attitude. The
sensitivity and operation mode (Normal mode/
AVCS mode) can be changed via a switch.
●Threerates(Rate1/Rate2/Rate3)canbeswitched.
●Upto3axes(Gyro/Gyro2/Gyro3)canbe
simultaneously controlled.
Note: This setting does not assign a sensitivity
channel. To do so, use the Linkage menu
prior to assigning the sensitivity channel
(Gyro/Gyro2/Gyro3). Be sure to select an
unused channel.
Set the [Control] and [Trim] settings other than
Function to [--].
●Theoperationmode(AVCS/
NOR)andsensitivityofthe
threeaxisGyro/Gyro2/Gyro3
can be set.
●Select[GYRO]attheModelmenuand
access the setup screen shown below
by pushing the RTN button.
(Active rate # display)
● Gyrotype
selection
● ACT/INH
● Switchselection
●Rate1-3setup
screen selection
[Rate1setupscreen]
[Rate2setupscreen]
[Rate3setupscreen]
Setting method
*Prior to using the Function menu in the Linkage menu to
assign the sensitivity channel (Gyro/Gyro2/Gyro3), select an
unused channel.
Set [Control] and [Trim] other than function to [--].
●Rate 1-3 setup screen selection
Move the cursor to the setup screen selection
item and push the RTN button to switch
tothedatainputmode.Selectthesetup
screen#byscrollingthePushdial.
PushtheRTNbuttontochangethesetup
screen and return to the cursor mode.
●Activate the function
Movethecursortothe[INH]itemandpush
the RTN button to switch to the data input
mode.SelecttheACTmodebyscrollingthe
Pushdial.
*The display blinks.
PushtheRTNbuttontoactivatethefunction
and return to the cursor mode.
●
Thenetuninghardware
setting
Settingrange:
GY type :Settingrate±20%(The
actual rate has not to be
greaterthan100%.)
NORM type : Settingrate±10.0%(The
actual rate has not to be greater
than100%.)
Scrolling
●Movingcursor
●Selectingmode
●Adjustingvalue
●Toinputdatamode
●Dataisentered