180
<Functions of Model Menu (Helicopter Functions)>
●Selectthefunctionname
andreturntotheModel
menubypushingthe RTN
buttonor pushingthe
HOME/EXITbutton.
<Push Dial>
RETURN
PIT to RUD mixing (Revolution mixing)
Use this mix when you want to suppress the
torque generated by main rotor pitch and speed
changes during pitch operation. Adjust so that the
nose does not move in the rudder direction.
<Normal condition mixing curve>
Themixingcurverateshouldbestarted
usingsmallervalues.
Forarotorwithaclockwiseoperation
direction,whenpitchwasinputattheplus
side,settheseparameterssothatmixing
isintheclockwisedirection.First,trimat
hoveringandthenadjusttheneutral
position.
1.Adjustmentbetweenslowandhovering
Repeatedlyhoverfromtakeoffandland
ataconstantratematchedtoyourown
rhythm.Adjustthepitchsothatthenose
ofthehelicopterremainssteadywhenthe
throttleisraisedandlowered.
2.Throttlehighside(climbinganddiving
fromhovering)
Repeatclimbinganddivingfromhovering
ataconstantratematchedtoyourown
rhythmandadjustthepitchsothatthe
nosedoesnotdeflectwhenthethrottleis
raisedandlowered.
Note: When a GY Series or other heading hold
gyro is used, since correction is performed by
the gyro, this mix is not utilized. If this function
is used when the gyro operation mode is the
AVCS mode, the neutral position will change.
<Idle up condition mixing curve>
Setthemixingratesothattherudderdirection
athigh-speedightisstraightahead.Adjustfor
eachconditionused.
●Select[PITtoRUD]attheModelmenuandaccess
thesetupscreenshownbelowbypushingthe
RTNbutton.
(Currently selected condition name)
Setting method
●Activate the mixing
Whenusingthisfunction,movethecursorto
the[ACT]itemandpushtheRTNbuttonto
switchtothedatainputmode.
SelecttheACTmodebyscrollingthePush
dial.
*The display blinks.
PushtheRTNbuttontoactivatethemixing
andreturntothecursormode.(ONis
displayed.)
●5-point curve setting
Movethecursortothecurveratesetting
itemyouwanttoadjustandpushtheRTN
buttontoswitchtothedatainputmode.
AdjusttheratebyscrollingthePushdial.
Initialvalue:P1~P5:0%
Adjustmentrange:-100%~+100%
*When the RTN button is pushed for one second, the rate is
reset to the initial value.)
PushtheRTNbuttontoendtheadjustment
andreturntothecursormode.
Repeatthisprocedureforeachpoint.
●Pitch curve copy function
MovethecursortoCOPYitemandpushthe
RTNbuttontoswitchtothedatainputmode.
Selectthecopydestinationconditionby
scrollingthePushdialandpushingtheRTN
button.Selectthe[YES]andpushtheRTN
button.
Scrolling
●Movingcursor
●Selectingmode
●Adjustingvalue
●Toinputdatamode
●Dataisentered