FAIL SAFE
Setstheservosoperatingpositionwhentransmittersignalscanno
longerbereceivedorwhenthereceiverbatteryvoltagedrops.
(The display screen is an example. The
screen depends on the model type.)
The Failsafe function may be used to set up
positions that the servos move to in the case of
radio interference.
You may set either of two positions for each
channel: Hold, where the servo maintains its last
commanded position, or failsafe, where each
servo moves to a predetermined position. You may
choose either mode for each channel.
The T12K system also provides you with an
advanced battery monitoring function that warns
you when the receiver battery has only a little
power remaining. In this case, each servo is
moved to the dened failsafe position. The battery
failsafe may be released by operating a predened
control on the transmitter (default is throttle),
do not continue to fly, land as soon as possible.
Remember, if the predefined control suddenly
moves to a position you did not command, land at
Fail safe setting procedure
1.Movethecursortothe"F/S"itemofthe
channelyouwanttosetandpushtheRTN
buttontoswitchtothedatainputmode.
2.SelecttheF/SmodebyscrollingthePush
dial.Aconrmationmessageappears.
*The display blinks.
3.PushtheRTNbutton.(PushtheS1buttonto
stopsetting.)
*The channel switches to the F/S mode.
4.Movethecursortothe"POS"item.
Holdthecorrespondingstick,knob,slider,
etc.inthepositionyouwanttheservo
tomovetowhenthefailsafefunctionis
activatedandpushtheRTNbuttonforone
second.
*The set position is displayed in percentage.
*If you want to return that channel to the hold mode, move
the cursor to the "F/S" item and push the RTN button to
switch to the data input mode. Select the F/S mode by
scrolling the Push dial. A conrmation message appears and
then change the mode by pushing the RTN button.
once and check your receiver battery.
Denes servo position when signals are lost and
when receiver battery voltage becomes low.
Warning
For safety, always set the fail safe functions.
●Remember to set the throttle channel fail safe function so that
the servo moves to the maximum slow side for airplanes and
to the slow side from the hovering position for helicopters.
Crashing of the model at full high when normal radio waves
cannot be received due to interference, etc., is very dangerous.
●If the battery fail safe is reset by the throttle stick, it may
be mistaken for an engine malfunction and will be reset at
throttle slow and the model will continue to y. If you have
any doubts, immediately land.
Battery fail safe setting procedure
Batteryfailsafecanbesetforeachchannel
bythesamemethodasthefailsafesetting
procedure.Selectandsetthe"B.F/S"item.
[ON]:BatteryfailsafefunctionON
[OFF]:BatteryfailsafefunctionOFF
Battery fail safe release switch setting
Thisfunctiontemporarilyreleasesthebattery
failsafefunctionsothefuselagecanrecover
afterthebatteryfailsafefunctionwas
activatedbyadropinthereceiverbattery
voltage.Thissettingselectstheswitchwhich
releasesthebatteryfailsafefunction.
1.Movethecursortothe[RELEASEB.F/S]itemin
thesetupscreen(lastpage).
2.PushtheRTNbutton.
*The switch selection screen is called.
*For a detailed description of the switch selection and ON/
OFF direction setting method, see [Switch Setting Method]
at the back of this manual.
●Select[FAILSAFE]intheLinkagemenuandaccess
thesetupscreenshownbelowbypushingtheRTN
button.
Scrolling
●Movingcursor
●Selectingmode
●Tonextpage
●Toinputdatamode
●Dataisentered