<Model Menu (Common Functions)>
PushtheRTNbuttontoendadjustmentand
returntothecursormode.
*Needle high trim works as high trim based on the center.
(Works like ATL trim.)
●Acceleration setting (Airplane)
*This function is used to adjust the needle/engine rise
characteristics during acceleration. This enables an
acceleration function which temporarily increases the needle
operation from the throttle stick.
This function is used when there are symptoms of the
mixture being too lean or too rich, which would be
generated by sudden throttle stick inputs.
[Accelerationratesetting(RATE)]
*Acceleration can be adjusted for both high and low settings.
[Dampingratesetting(DUMPING)]
*The return time after operation (Dumping) can be set.
Movethecursortotherateitemyouwantto
changeandpushtheRTNbuttontoswitch
tothedatainputmode.
AdjusttheratebyscrollingthePushdial.
*When the RTN button is pushed for one second, the rate is
reset to the initial value.)
PushtheRTNbuttontoendadjustmentand
returntothecursormode.
[Operationpointsetting(ACTPOS)]
*The operation point at which the acceleration setting will
occur. If this point is exceeded, acceleration is performed.
Movethecursortothe[ACTPOS]itemand
holdthethrottlesticktothepositionyou
wanttochange.PushtheRTNbuttonforone
second.
Note: When using the acceleration function,
since the needle stroke is large, adjust your
settings so there is no binding of your linkage.
●Engine cut setting
* Operation linked with the throttle hold function, throttle cut
function, and idle down function is possible. The throttle
cut position can be adjusted accordingly. Set it to the fully
closed position.
Movethecursortothethrottlecutoridle
downitemandpushtheRTNbuttontoswitch
tothedatainputmode.
AdjusttheservopositionbyscrollingthePush
dial.
Initialvalue:THRCUT:17%,IDLEDOWN:0%
Adjustmentrange:THRCUT:0~50%,IDLE
DOWN:0~100%
*When the RTN button is pushed for one second, the rate is
reset to the initial value.)
PushtheRTNbuttontoendtheadjustment
andreturntothecursormode.
Setting method
*Before using this function, assign the [FUEL MIX] function
to an unused channel in the Linkage menu [FUNCTION] .
●Activate the function.
1.Movethecursortothe[ACT]itemandpush
theRTNbuttontoswitchtothedatainput
mode.
SelecttheACTmodebyscrollingthePush
dial.
*The display blinks.
PushtheRTNbuttontoactivatethefunction
andreturntothecursormode.(ONis
displayed.)
2.Movethecursortothe[MIX]itemandpush
theRTNbuttontoswitchtothedatainput
mode.
Selectthemixingmodeyouwanttochange
byscrollingthePushdial.
*The display blinks.
PushtheRTNbuttontochangethemode
andreturntothecursormode.
*When [MIX] is selected at the [MIX] icon, the throttle curve
data that is set becomes the mix master. When [UNMIX] is
selected, the throttle stick position becomes the master.
●5-point curve setting
1.Movethecursortothepointratesettingitem
youwanttoadjustandpushtheRTNbutton
toswitchtothedatainputmode.
AdjusttheratebyscrollingthePushdial.
Initialvalue:0%
Adjustmentrange:-100%~+100%
*When the RTN button is pushed for one second, the servo
operation position is reset to the initial value.)
PushtheRTNbuttontoendadjustmentand
returntothecursormode.
2.Repeatthisprocedureforeachpoint.
●Needle high trim setting
1.Movethecursortotheneedlehightrim
selectionitemandaccesstheswitchsetup
screenbypushingtheRTNbutton.Selectthe
needlehightrimlever.
*For a detailed description of the setting method, see [Switch
Setting Method] at the back of this manual.
2.MovethecursortotheTRIMrateitemand
pushtheRTNbuttontoswitchtothedata
inputmode.
AdjustthetrimratebyscrollingthePushdial.
Initialvalue:0%
Adjustmentrange:-30%~+30%
*When the RTN button is pushed for one second, the rate is
reset to the initial value.)