EasyManua.ls Logo

FUTABA T12K

FUTABA T12K
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
176
<Functions of Model Menu (Helicopter Functions)>
Throttle limiter function
Setting method
*Set at the 3rd page of the throttle curve screen.
•Activate the function.
1.SelectACTandpushtheRTNbutton.
2.SwitchthedisplaytoACTbyscrollingthe
Pushdial.
*Thedisplayblinks.
INH:Inhibit
ACT:Activate
3.EntertheselectionbypushingtheRTN
button.
•ON/OFF switch setting
1.SelectSWandpushtheRTNbutton.
2.TheH/WSETscreenisdisplayed.Selectthe
hardwareandpushtheRTNbutton.
This function limits the high range of the throttle
movement by any slider or trimmer.
*Control which adjusts the limit point during ight can be set.
•High side operating range setting
1.SelectHIGHandpushtheRTNbutton.
2.Adjustthehighsideoperatingrangeby
scrollingthePushdial.
*A gauge is displayed at the left side of the graph.
3.PushtheRTNbuttontoswitchtothecursor
mode.
•Low side operating range setting
1.SelectLOWandpushtheRTNbutton.
2.Adjustthelowsideoperatingrangeby
scrollingthePushdial.
*A gauge is displayed at the left side of the graph.
3.PushtheRTNbuttontoswitchtothecursor
mode.
•Limiter operating range adjustment control
setting
1.SelectCTRLandpushtheRTNbutton.
2.TheH/WSETscreenisdisplayed.Selectthe
hardwareandpushtheRTNbutton.
*The throttle limiter operating position is indicated by a
dotted line on the graph.
*When limiter operating range adjustment control is NULL,
the throttle limiter function is not performed.
•Changing the control center position
1.SelectCENTERandpushtheRTNbuttonfor1
second.CENTERchangesfromINHto“rate
display”.
2.WhentheCENTERrateischanged,the
neutralpositionofthehardwaresetatCTRL
canbeadjusted.
*When CENTER is INH, the neutral position becomes the
LOW intermediate value.
*When CENTER is changed from INH to “rate display”, the
CENTER rate is set to the LOW intermediate value.
*The CENTER rate can be set between HIGH and LOW.
[Throttlelimitersetting]
When "CTRL" is set as a "RS" side slider.
The state of full high of a throttle stick.
“RS”Position
Throttle
Position
Full
RestrictionRestriction
Restriction
Slow
Full
Slow
Full
Slow
In "INH", the halfway
point of "HIGH" and
"LOW".
HIGH
LOW
CENTER

Table of Contents

Other manuals for FUTABA T12K

Related product manuals