Safety airbag-18
Impact-vehicle diagnosis
Test SRS-ECU diagnostic signals
1. Connect the (X-431 diagnostic test’s) diagnostic joint
2. Read the diagnostic results with X-431 diagnostic tester
Repairing procedure
1.When safety airbag is released.
The following parts should be replaced with new ones
a. Passengers’ side safety airbag module
b. SRS-ECU
c. Driver’s side safety airbag module
2 Check the following parts; replace them with new ones providing something wrong with them.
a. Clock spring
b. Steering-wheel, steering column, bottom steering shaft module
3.Driver’s side safety airbag module’s installation status towards the steering wheel.
a. Check whether abnormal knocking is with the steering wheel, its activity is in good condition and its clearance is normal.
b. Check whether the wiring harness joint is broken and its terminal is deformed.
Caution: Due to the impact, the diagnostic instrument cannot communicate with SRS-ECU when accumulator is lack of
power, in this case, check and maintain the instrument panel wiring harness or utilize the extension power supply.