EasyManua.ls Logo

Great Wall hover - Operation of Solenoid Valve During Shifting Period

Great Wall hover
425 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Automatic transmission-12
Shifting Initial shifting status Current variation of S5 Finished shifting status
1-2
S1 Off
S4 On
950mA-650mA
S4 Off
1-3
S1 Off
S2 Off
S3 On
S4 On
900mA-400mA
S3 Off
S4 Off
1-4
S2 Off
S3 On
S4 On
850mA-750mA
S3 Off
S4 Off
2-3
S2 Off
S3 On
S4 On
700mA-200mA
S3 Off
S4 Off
3-4
S1 On
S4 On
950mA-550mA
S4 Off
4-3 S4 On 950mA-700mA
S1 Off
S4 Off
4-2 S3 On 800mA-500mA
S1 Off
S2 On
S3 Off
4-1
S3 On
S4 On
1000mA-600mA
S2 On
S3 Off
S4 Off
3-2
S2 On
S4 On
550mA-400mA @ 20kph
800mA-600mA@60kph
1000mA-800mA@100kph
S4 Off
3-1
S3 On
S4 On
1000mA-750mA
S1 On
S2 On
S3 Off
S4 Off
2-1 S4 On 1000mA-500mA
S1 On
S4 Off
Torque converter clutch
On
Off
S7 On
1000mA-500mA
900mA-600mA
S7 Off
Table 3.6 Operation of solenoid valve during shifting period

Table of Contents

Related product manuals