Global: Menu Command Touch Panel Calibration
217
Touch Panel Calibration
If your input in the display is not detected as you expect, or
if the edit cell moves to a location in the display other than
where you pressed, you should calibrate the display as
follows.
To ensure optimal calibration, touch the center of each
symbol (calibration target) shown in the corners of the
display as accurately as you can.
1. Choose “Touch Panel Calibration” to access the dialog
box.
If you're unable to choose this command from the page
menu, you can access it by holding down the ENTER
button in P0 and pressing the 3 button.
2. Lightly press the center of the target that appears in the
upper left of the screen.
If you decide to cancel the operation, press the EXIT but
ton.
When your touch on the target has been detected, the tar
get will move.
3. Lightly press the center of the target that appears in the
lower right of the screen.
If you decide to cancel the operation, press the EXIT but
ton.
When your touch on the target has been detected, the
touchscreen will be calibrated, and the screen will ask
you to verify the result.
4. Touch the three targets to verify that calibration was
successful.
When you touch a target, a ballshaped symbol will
appear.
The closer the center of the ball is to the center of the tar
get, the more accurately calibration was performed. You
can press the target again as many times as you like.
5. If desired, you can press the Redo button to return to
step 2 and perform the calibration again.
6. If you are satisfied with the touch response, press the
OK button (or the ENTER button) to end the procedure.
7. Press the EXIT button, and you will return to the state
prior to executing the calibration function.
If in steps 2 or 3 you pressed a screen location that was
significantly distant from the center of the “+” target,
the detection points for the Redo button and OK button
will also be skewed. If you're unable to press these
buttons successfully, try pressing the area around them.
Alternatively, press the EXIT button to exit the
procedure, and then perform the Touch Panel
Calibration operation once again.
Half Damper Calibration
Half Damper Calibration is available on the Basic Setup
page.
If a damper pedal that supports half damper (the DS–1H
option) is connected to the DAMPER jack, here’s how you
can adjust the sensitivity if the damper effect is not applied
appropriately.
Since the halfdamper pedal is highly sensitive, please
use the optional DS–1H. Other pedals may not produce
the appropriate effect, or may be impossible to calibrate
correctly.
1. Connect a half-damper pedal to the DAMPER jack.
2. Select “Half Damper Calibration” to open the dialog
box.
3. Press the half-damper pedal, and then release your foot
from the pedal.
4. Press the Done button.
If the adjustment could not be performed correctly, an error
message will be displayed. Please perform the procedure
once again.