17 Malfunction, cause and remedy
17.5 Faults of the electrics/electronics
212
Comprima V 180
Original Operating Instructions 150001053_00_en
521106-
Supply voltage of sensors
Possible cause Remedy
FMI 11: The error cause is unknown.
The supply voltage of the
sensors could not be activ-
ated.
Note the error number with the FMI and contact the KRONE
service partner.
521107-
Supply voltage for the KRONE Machine Controller (KMC) at connection UE
Possible cause Remedy
FMI 3: An overvoltage or a short circuit to the supply voltage has occurred.
The cabling is faulty.
Check the cabling for damage, refer to page202.
One or several sensors/actu-
ators connected to the voltage
group are defective.
An overview of the position of the sensors, actuators and
control units is provided in the circuit diagram, refer to
page231.
Check the sensor and cabling for damage, refer to
page202.
The control unit KMC is de-
fective.
Replace the control unit KMC.
Note the error number with the FMI and contact the KRONE
service partner.
521107-
Supply voltage for the KRONE Machine Controller (KMC) at connection UE
Possible cause Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
The cabling is faulty.
Check the cabling for damage, refer to page202.
One or several sensors/actu-
ators connected to the voltage
group are defective.
An overview of the position of the sensors, actuators and
control units is provided in the circuit diagram, refer to
page231.
Check the sensor and cabling for damage, refer to
page202.
The control unit KMC is de-
fective.
Replace the control unit KMC.
Note the error number with the FMI and contact the KRONE
service partner.
521108-
The voltage group (UB1) has not passed the self-test.
Possible cause Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
There is a cable break or
short circuit.
Note down the error number on the FMI and contact the
KRONE service partner.