Malfunction, cause and remedy 17
Faults of the electrics/electronics 17.5
Comprima V 180
Original Operating Instructions 150001053_00_en 221
Possible cause Remedy
The wiring of the sensor is de-
fective.
Check sensor and wiring for damage, refer to page202.
522161-
B61
M1
SensorB61 “Tying 1 (passive)”
Possible cause Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
FMI 5: A cable break has occurred or the current intensity is too weak.
The sensor shows external
damage.
Check sensor and wiring for damage, refer to page202.
The wiring of the sensor is de-
fective.
522162-
B62
SensorB62 “Tying 2 (active)”
Possible cause Remedy
FMI 4: An undervoltage or a short circuit to ground has occurred.
FMI 5: A cable break has occurred or the current intensity is too weak.
The sensor shows external
damage.
Check sensor and wiring for damage, refer to page202.
The wiring of the sensor is de-
fective.
522300-
M01
M1
ActuatorM01 “Motor tying 1 (passive)”
Possible cause Remedy
FMI 5: A cable break has occurred or the current intensity is too weak.
FMI 6: There is a short circuit to ground or current intensity is too low.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage, refer to page202
The wiring of the actuator is
faulty.
522301-
K01
ActuatorK01 “Pick-up”
Possible cause Remedy
FMI 5: A cable break has occurred or the current intensity is too weak.
FMI 6: There is a short circuit to ground or current intensity is too low.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage, refer to page202
The wiring of the actuator is
faulty.
522402-
E10
Actuator E10 “Warning beacon”