17 Malfunction, cause and remedy
17.5 Faults of the electrics/electronics
222
Comprima V 180
Original Operating Instructions 150001053_00_en
Possible cause Remedy
FMI 5: A cable break has occurred or the current intensity is too weak.
FMI 6: There is a short circuit to ground or current intensity is too low.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage, refer to page202
The wiring of the actuator is
faulty.
522420-
ActuatorE20/E21 "Working lights net roll (for the “Net and chamber film wrapping” and
“Working lights” version)"
Possible cause Remedy
FMI 5: A cable break has occurred or the current intensity is too weak.
FMI 6: There is a short circuit to ground or current intensity is too low.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage, refer to page202
The wiring of the actuator is
faulty.
522421-
ActuatorE21 "Working lights chamber film wrapping (for the “Net and chamber film
wrapping” version)"
Possible cause Remedy
FMI 5: A cable break has occurred or the current intensity is too weak.
FMI 6: There is a short circuit to ground or current intensity is too low.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage, refer to page202
The wiring of the actuator is
faulty.
522422-
ActuatorE22/E23 “Maintenance lighting side hood left/right”
Possible cause Remedy
FMI 5: A cable break has occurred or the current intensity is too weak.
FMI 6: There is a short circuit to ground or current intensity is too low.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage, refer to page202
The wiring of the actuator is
faulty.
522500-