Malfunction, cause and remedy 17
Faults of the electrics/electronics 17.5
Comprima V 180
Original Operating Instructions 150001053_00_en 223
Possible cause Remedy
FMI 13: The wrong configuration values were saved.
An invalid machine type has
been specified.
Adjust the machine type.
Restart the machine.
The configuration parameters
of the machine are invalid.
Configure the machine correctly.
Restart the machine.
522530-
KMB1
Possible cause Remedy
FMI 31: The condition has been fulfilled.
The wiring is faulty.
Check wiring.
The control unit is defective.
Note the error number with the FMI and contact the KRONE
service partner.
522531-
KMB1
Possible cause Remedy
FMI 19: There is a CAN communication malfunction.
The wiring is faulty.
Check wiring.
The control unit is defective.
Note the error number with the FMI and contact the KRONE
service partner.
522532-
KMB2
Possible cause Remedy
FMI 31: The condition has been fulfilled.
The wiring is faulty.
Check wiring.
The control unit is defective.
Note the error number with the FMI and contact the KRONE
service partner.
522533-
KMB2
Possible cause Remedy
FMI 19: There is a CAN communication malfunction.
The wiring is faulty.
Check wiring.
The control unit is defective.
Note the error number with the FMI and contact the KRONE
service partner.
522540-
FM 1
Possible cause Remedy
FMI 31: The condition has been fulfilled.
The wiring is faulty.
Check wiring.
The control unit is defective.
Note the error number with the FMI and contact the KRONE
service partner.