6-32 824 Reference Manual 11/8/00
•Dose
Projected dose
Time Weighted Average
Sound Exposure Level
Elapsed Time
The
Exposure-a
display is shown below:
The following explains each of the display’s components:
Display label -
This shows the current display (for example,
SLM Exposure-a
”).
Dose
- By definition, a person receives 100% dose when
exposed to a noise having a TWA equal to the selected crite-
rion level for a time equal to the criterion time (usually eight
hours). This corresponds to the maximum safe noise expo-
sure. Exposures at higher levels will result in a 100% dose in
less time; or if exposure continues, the exposure will exceed
100% dose.
Projected dose
- Projected dose is the dose that will occur if
current noise levels continue for the entire criterion time.
Time weighted average
- This display shows the Time
Weighted Average (TWA) measured in dB.
Sound exposure level
- This display shows the Sound
Exposure Level (SEL) measured in dB.
Display label
Sound exposure level
Time weighted average
Dose
Projected Dose
Elapsed Time

Table of Contents

Other manuals for Larson Davis System 824

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Larson Davis System 824 and is the answer not in the manual?

Larson Davis System 824 Specifications

General IconGeneral
BrandLarson Davis
ModelSystem 824
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals