17 Function library
17.2 System blocks | LS_ParFix
1539
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.2.16 LS_ParFix
This system block outputs various fixed values (constants) to be used in the interconnection.
From version 11.00.00, another LS_ParFix_2 system block is available which can be used e.g. in
the application level.
Outputs
Designator
Data type
Value/meaning
bTrue
BOOL
1 TRUE
nPos100_a
INT
16384 + 100 %
nNeg100_a
INT
-16384 - 100 %
nPos199_99_a
INT
32767 + 199.99 %
nNeg199_99_a
INT
-32767 - 199.99 %
w65535
WORD
65535 0xFFFF
wDriveCtrl
WORD
9 0x0009
Bit 0, SwitchOn = TRUE
Bit 3, EnableOperation = TRUE
All others: FALSE
See also:
wCANControl/wMCIControl control words
( 129)