17 Function library
17.1 Function blocks | L_ComparePhi_3
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.30 L_ComparePhi_3
This FB compares two angle signals.
Comparison operation, hysteresis and window size can be parameterised.
Inputs
Outputs
Parameters
Designator
Data type
Information/possible settings
dnIn1_p
DINT
Input signal 1
dnIn2_p
DINT
Input signal 2
Designator
Data type
Value/meaning
bOut
BOOL
Status signal "Comparison statement is true"
TRUE The statement of the selected comparison mode is true.
Parameters Possible settings Info
C01670/3 Function selection
1 dnIn1 = dnIn2
2 dnIn1 > dnIn2
3 dnIn1 < dnIn2
4 |dnIn1| = |dnIn2|
5 |dnIn1| > |dnIn2|
6 |dnIn1| < |dnIn2|
C01671/3
0 Incr. 1073741824 Hysteresis
Lenze setting: 0 incr.
C01672/3
0 Incr. 1073741824 Window
Lenze setting: 0 incr.