Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 421
7 Technology applications
7.3 TA "actuating drive speed (AC Drive Profile)"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.3.4.6 PC
Connection Assignment Connection Assignment
X101/NC-NO LA_NCtrl.bDriveFail
X5/RFR LA_NCtrl.bFailReset X3/A1U -
X5/DI1 - X3/A1I -
X5/DI2 - X3/A2U -
X5/DI3 - X3/A2I -
X5/DI4 - X3/O1U LA_NCtrl.nMotorSpeedAct_a *
X5/DI5 - X3/O1I -
X5/DI6 - X3/O2U -
X5/DI7 - X3/O2I -
* 10 V 100 % reference speed (C00011
)
X107/BD1 - X4/DO1 LA_NCtrl.bDriveReady
X107/BD2 - X4/DO2 -
X4/DO3 -
X4
24B 24O
GB DO1
BD2 DO3
GO
BD1 DO2
A2I
AR
COM
A1U
NC
A2U
A1I
NO
X3
DI3
DI2
DI4
DI5
DI6
DI7
GI
24I
DI1
RFR
GA
O1U
O1I
O2U
O2I
X101
24E
+
=
CG
CL
CH
X1
X5
X107
Actual speed value
Controller enable / reset error
DriveReady
External
supply
24 V DC
DriveFail

Table of Contents