7 Technology applications
7.3 TA "actuating drive speed (AC Drive Profile)"
432
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Configuration parameters for "GeneralPurpose" functions
[7-10] "GeneralPurpose" functions
nGPAnalogSwitchOut_a
nGPAnalogSwitchIn1_a
0
1
nGPMulDivIn_a nGPMulDivOut_a
bGPDigitalDelayOut
bGPDigitalDelayIn
bGPLogicIn1
&
0
1
>
1
000
001
1
0
1
1
1
0
...
2
3
4
0
1
bGPLogicOut
bGPCompareOut
nGPCompareIn1_a
nGPCompareIn2_a
f
=
nGPAnalogSwitchIn2_a
bGPAnalogSwitchSet
C00699/1
C00699/2
C00720/1 C00720/2
C00821/2
C00821/1
C00821/3
C00821/8
bGPLogicIn2
bGPLogicIn3
C00820
C00680
C00682C00681
C00830/82
C00833/66
C00833/63
C00833/64
C00833/65
C00830/16
C00830/17
C00830/14
C00830/15
C00833/13
In
Out
±32767
±( 199.99%)
LA_NCtrl
Configuration parameters Entry in select list
C700/9
C700/10
C701/23
C700/13
C701/24
C701/25
C701/26
C701/27
C700/14
C700/15
1006
1008
1008
1009
1017
GeneralPurpose (GP) functions
nGPArithmetikOut_a
nGPArithmetikIn1_a
nGPArithmetikIn2_a
C00830/12
C00830/13
(In1 * 100%)5
(In1 * In2)3
(In1 * 1%)4
In1 - In22
In1 + In21
In10
C00338
100%
|In2|
(100% - In2)
In1
In2
Out =
±32767
±( 199.99%)
C700/11
C700/12
1007
bGPSignalOut1
C00411/1 C00412 - Bit 0
0
1
C00411/2
C00411/3
C00411/4
bGPSignalOut2
C00412 - Bit 1
0
1
bGPSignalOut3
C00412 - Bit 2
0
1
bGPSignalOut4
C00412 - Bit 3
0
1
1010
1011
1012
1013

Table of Contents

Other manuals for Lenze 8400

Related product manuals