Loading...
Parameter Name / value range / [default seng] Info
Bit 9 Operaon mode specic
Bit 10 Reserv
ed
Bit 11 Override coast
Bit 12 AutoInit
Bit 13 Reserved
Bit 14 Release holding brake
Bit 15 Reserved
0x6041
(PAR 780)
Statusword
(Statusword)
Read only
Mappable CiA402 status word with bit assignment in compliance with
CiA402 device prole.
Bit 0 Ready to switch on
Bit 1 Switched on
Bit 2 Operaon enabled
Bit 3 Fault acve
Bit 4 Voltage enabled
Bit 5 Quick stop
Bit 6 Switch on disabled
Bit 7 Warning acve
Bit 8 Deacvate RPDOs 1 ≡ cyclic PDOs have been deacvated.
Bit 9 Remote 1 ≡ inverter can receive commands via network.
Bit 10 Target reached 1 ≡ the actual posion is in the window.
Bit 11 Internal limit acve 1 ≡ internal limitaon of a setpoint acve.
Bit 12 Operaon mode acve
Bit 13 Following error
Bit 14 Holding brake released
Bit 15 Safe torque o (STO) not acve
Addional funcons
Device prole CiA402
179
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives.com