Parameter Name / value range / [default seng] Info
0x2631:002
(PAR 400/002)
Funcon assignment: Start enable
(Funcon lis
t: Start enable)
Seng can only be changed if controller inhibit is
acve.
For possible sengs see descripon for
0x2631:001 (PAR 400/001). ^ 188
Assignment of a trigger for the "Start enable" funcon.
Trigger = FALSE-TRUE edge: Drive is started in forward rotang direcon
(CW) if the following condions are fullled:
Controller is enabled and no error or quick st
op are acve.
No other start command is congured (start-forwards/start-back-
wards/run-for
wards/run-backwards = "Not connected [0]").
Trigger = TRUE-FALSE edge: drive is stopped again.
Notes:
If the controller enable is set = "Constant TRUE [1]", the only permissi-
ble trigger for this funcon is a digital input (otherwise the error mes-
sage "Connected incorrectly" appears).
The stop method can be selected in 0x2838:003 (PAR 203/003).
The funcon also serves to realise an automac start aer switch-on.
4Starng performance ^
72
11 Digital input 1 State of X3/DI1, taking an inversion set in 0x2632:001 (PAR 411/001) into
consideraon.
0x2631:003
(PAR 400/003)
Funcon assignment: Quick stop
(Funcon list: Quick stop)
Seng can only be changed if controller inhibit is
acve.
For possible sengs see descripon for
0x2631:001 (PAR 400/001). ^ 188
Assignment of a trigger for the "Quick stop" funcon.
Trigger = TRUE: "Quick stop" funcon acvated.
Trigger = FALSE: no acon / deacvate funcon again.
Notes:
The "Quick stop" funcon brings the motor to a standsll within the
deceleraon me set in 0x291C (PAR 225).
The "Quick stop" funcon has a higher priority than the "Start enable"
funcon.
00 Not connected No trigger assigned (trigger is constantly FALSE).
0x2631:006
(PAR 400/006)
Funcon assignment: Forward start (CW)
(Funcon list: Forward start)
Seng can only be changed if controller inhibit is
acve.
For possible sengs see descripon for
0x2631:001 (PAR 400/001). ^ 188
Assignment of a trigger for the "Forward start (CW)" funcon.
Trigger = FALSE-TRUE edge: drive is started in forward rotang direcon
(CW).
Trigger = FALSE: no acon.
Notes:
In order to start the drive with this funcon, the "Start enable" func-
on has to be assigned to a trigger in order to provide a stop com-
mand.
Aer the start, the drive runs unl the start enable is deacvated
again or another stop command is given.
In the case of a bipolar setpoint selecon (e.g ±10 V), the funcon is
executed irrespecve of the rotang
direcon. The rotang direcon
is determined by the sign of the setpoint.
The "Reversal" funcon (0x2631:013 (PAR 400/013)) can be used in
connecon with this funcon.
The use of the "Forwar
d start (CW)" and "Backward start (CCW)" func-
ons excludes the use of the "Forward run (CW)" and "Backward run
(CCW)" and vice versa (produces a "Incorr
ectly connected" error mes-
sage).
00 Not connected No trigger assigned (trigger is constantly FALSE).
Flexible I/O conguraon
Controller enable, starng & stopping, reversal
190