Parameter Name / value range / [default seng] Info
0x2634:001
(PAR 420/001)
Funcon assignment of digital outputs: R
elay
(Digital outputs: Relay funcon)
For possible sengs see descripon for
0x2634:001 (PAR 420/001). ^ 215
Assignment of a trigger to the relay.
Trigger = FALSE: X9/NO-COM open and NC-COM closed.
Trigger = TRUE: X9/NO-COM closed and NC-COM open.
Notes:
An inversion set in 0x2635:001 (PAR 421/001)is taken into considera-
on here.
51 Ready for operaon TRUE if operaon is enabled AND no error is acve. Otherwise FALSE.
0x2634:002
(PAR 420/002)
Funcon assignment of digital outputs: Digital output
1
(Digital outputs: DO1 funcon)
For possible sengs see descripon for
0x2634:001 (PAR 420/001). ^ 215
Assignment of a trigger to digital output 1.
Trigger = FALSE: X3/DO1 set to LOW level.
Trigger = TRUE: X3/DO1 set to HIGH level.
Notes:
An inversion set in 0x2635:002 (PAR 421/002) is taken into considera-
on here.
115 Release holding brake TRUE if the holding brake is released (or should be released). Otherwise
FALSE.
All funconal possible sengs for controlling the inverter are described in the "Flexible I/O
conguraon" chapter.
^ 186
Commissioning
Parameter seng
Funcon assignmen
t of the inputs and outputs
23