PAR Name / SUB xxx: Name Default seng Seng range Address
SUB 004: Power cycles - - (Read only) 0x2D81:004
SUB 005
: Relay cycles - - (Read only) 0x2D81:005
SUB 006: Short-circ. counter - - (Read only) 0x2D81:006
SUB 007: Earth fault counter - - (Read only) 0x2D81:007
SUB 008: Clamp acve - - (Read only) 0x2D81:008
SUB 009: Fan oper. me x s - (Read only) 0x2D81:009
PAR 155 Fault memory
SUB 000: Keypad display - - (Read only) 0x2006:000
PAR 190 SUB 001: Product code - - (Read only) 0x2000:001
SUB 002: Serial number - - (Read only) 0x2000:002
SUB 004: CU rmware ver. - - (Read only) 0x2000:004
SUB 005: CU rmware type - - (Read only) 0x2000:005
SUB 006: CU bootlder ver. - - (Read only) 0x2000:006
SUB 007: CU bootlder type - - (Read only) 0x2000:007
SUB 008: OBD version - - (Read only) 0x2000:008
SUB 010: PU rmware ver. - - (Read only) 0x2000:010
SUB 011: PU rmware type - - (Read only) 0x2000:011
SUB 012: PU bootlder ver. - - (Read only) 0x2000:012
SUB 013: PU bootlder type - - (Read only) 0x2000:013
PAR 191 Device name My Device Text 0x2001
PAR 197 Protecon status - - (Read only) 0x2040
PAR 198 Status of load. par - - (Read only) 0x2827
PAR 200 Control source Terminal mode [0] Selecon list 0x2824
PAR 201 Standard setpoint
SUB 001: Frequency setp. Analog input 1 [2] Selecon list 0x2860:001
SUB 002: PID setpoint Keyp.PID
.setp. [1] Selecon list 0x2860:002
SUB 003: Torque setp. Analog input 1 [2] Selecon list 0x2860:003
PAR 202 Keypad setpoints
SUB 001: KP freq. setp. 20.0 Hz 0.0 ... 599.0 Hz 0x2601:001
SUB 002: KP PID setp. 0.00 PUnit -300.00 ... 300.00 PUnit 0x2601:002
PAR 203 Start/stop confg
SUB 001: Start method Normal [0] Selecon list 0x2838:001
SUB 002: Start at switch-on OFF [0] Selecon list 0x2838:002
SUB 003: Stop method Standard Ramp [1] Selecon lis
t 0x2838:003
PAR 208 Mains volt. se.
SUB 001: AC input volt. 230 Ve [0] Selecon list 0x2540:001
SUB 002: LU warning level 0 V * 0 ... 800 V 0x2540:002
SUB 003: LU error level x V - (Read only) 0x2540:003
SUB 004: LU deleon level x V - (Read only) 0x2540:004
SUB 005: OU warning level 0 V * 0 ... 800 V 0x2540:005
SUB 006: OU error level x V - (Read only) 0x2540:006
SUB 007: OU deleon level x V - (Read only) 0x2540:007
P
AR 210 Min. frequency 0.0 Hz 0.0 ... 599.0 Hz 0x2915
PAR 211 Max. frequency 50.0 Hz 0.0 ... 599.0 Hz 0x2916
PAR 220 Acceleraon me 1 5.0 s 0.0 ... 3600.0 s 0x2917
PAR 221 Deceleraon me 1 5.0 s 0.0 ... 3600.0 s 0x2918
PAR 222 Acceleraon me 2 5.0 s 0.0 ... 3600.0 s 0x2919
PAR 223 Deceleraon me 2 5.0 s 0.0 ... 3600.0 s 0x291A
PAR 224 Switch ramp 0.0 Hz 0.0 ... 599.0 Hz 0x291B
PAR 225 QSP dec. me 1.0 s 0.0 ... 3600.0 s 0x291C
PAR
226 S-ramp char.
SUB 001: S-Ramp smoothing 0.0 % 0.0 ... 100.0 % 0x291E:001