Parameter Name / value range / [default seng] Info
Bit 5 Speed 2 limited 1 ≡ input of speed controller 2 in torque mode in limitaon.
Bit 6 Upper speed limit acve 1 ≡ speed is limited to upper speed limit in torque mode .
Bit 7 Lower speed limit acve 1 ≡ speed is limited to lower speed limit in torque mode .
Bit 8 Reserved -
Bit 9
Bit 10 Output frequency limited 1 ≡ setpoint frequency with V/f operaon in limitaon.
Bit 11 Magnesaon completed 1 ≡ during V/f operaon, the factor 7 rotor me constant has passed
(calculated from the me a
t which the inverter was enabled without
restart on the y and with a total motor current of 20 % rated motor cur-
rent for the rst me). Otherwise 0.
Bit 12 Motor phase error 1 ≡ motor phase failure detecon acve.
Bit 13 Reserved -
Bit 14 Blocking me for error reset is acve 1 ≡ the fault can only be reset when the blocking me has elapsed.
Bit 15 Reserved -
0x2833 Lenze status word 2
•
Read only
Bit-coded Lenze status word.
Bit 0 Reserved -
Bit 1 Manual test mode acve 1 ≡ manual test mode acve.
Bit 2 Manual control acve 1 ≡ manual control acve.
Bit 3 Reserved -
Bit 4
Bit 5
Bit 6 DC braking acve 1 ≡ DC braking acve.
Bit 7 Reserved -
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
0x2DAC
(PAR 119)
Keypad st
atus
(Keypad status)
•
Read only
Bit-coded display of the keypad status.
Bit 0 Start Key 1 ≡ keypad key acvated.
Bit 1 Stop Key
Bit 2 Up arrow
Bit 3 Down arrow
Bit 4 Enter Key
Bit 5 Back key
Bit 6 Reserved -
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
0x2DAD
(PAR 120)
Internal hardw
are states
(Int. HW states)
•
Read only
Bit-coded display of internal hardware states.
Bit 0 Relay 0 ≡ X9/NO-COM open and NC-COM closed.
1 ≡ X9/NO-COM closed and NC-COM open.
Diagnoscs and fault eliminaon
Diagnoscs
Inverter diagnoscs
52