1
2
3
4
5
6
7
8
© 2011 MIMAKI ENGINEERING CO.,LTD. 1.2.1 R.2.0 P.1
Maintenance Manual > Operating Principle > Maintenance Function > Carriage out
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver 1.80 / 1.00 Remark
2.0
1.2.1 Carriage out
LCD display
Process sequence
For other than the “service mode”, to prevent dryness of the nozzle surface and inside the cap, the warning sound
beeps at intervals of 30 seconds during carriage out.
STEP. Processing Description
1Start
1. Moves the table downward to the lowest position.
2. The Y bar comes to the front.
3. Performs cap OFF and moves the head to the maintenance position.
4. The wiper comes to the front.
2 Performing maintenance
1. The wiper pump operates periodically while maintenance is being
performed.
2. Message of maintenance is completed is displayed. Terminate with the
[ENTER].
3End
1. The wiper returns to the wiper origin position (aftermost).
2. The head caps ON.
3. If the warning of cap cleaning is displayed, clear it.
4. Clear the counter for the warning of cap cleaning.
STATION
PLEASE WAIT
MAINTENANCE
STATION <ENT>
STATION
MENT :CARRIAGE
STATION
COMPLETED <ENT>