© 2013 MIMAKI ENGINEERING CO.,LTD.
7.1.2 P.2
7.1.2 List of Error Messages
1
2
3
4
5
6
7
8
9
ERROR 146
E-LOG SEQ
Sequential number abnormality of the
event log
1. Initialize a Event log.
2. Replace the Main PCB with a new one. (Refer to 3.3.1)
10
ERROR 151
Main PCB V1R2
Main board 1.2V power supply is
abnormal.
1. Replace the Main PCB with a new one. (Refer to 3.3.1)
11
ERROR 152
Main PCB V2R5
Main board 2.5V power supply is
abnormal.
1. Replace the Main PCB with a new one. (Refer to 3.3.1)
12
ERROR 153
Main PCB V3R3
Main board 3.3V power supply is
abnormal.
1. The output voltage check of the Power supply PCB.
2. Replace the Power supply PCB with a new one. (Refer
to 6.4.1)
3. Replace the Main PCB with a new one. (Refer to 3.3.1)
13
ERROR 154
Main PCB V05
Main board 5V power supply is abnormal.
14
ERROR 155
Main PCB V35-1
Main board 35-1V power supply is
abnormal.
15
ERROR 156
Main PCB V5B
Main board 5VB power supply is
abnormal.
16
ERROR 157
Main PCB VTT
Main board VTT power supply is
abnormal.
1. Replace the Main PCB with a new one. (Refer to 3.3.1)
17
ERROR 158
Main PCB V352
Main board 35-2V power supply is
abnormal.
1. Replace the Main PCB with a new one. (Refer to 3.3.1)
18
ERROR 16e
Main PCB V3R3B
Main board 3.3VÇa power supply is
abnormal.
1. Replace the Main PCB with a new one. (Refer to 3.3.1)
19
ERROR 15f
HEAD DRIVE HOT
COM driver becomes the high
temperature.
1. Confirm movement of Slider Relay Cooling Fan.
2. Disconnect and connect the FFC located between the
Slider PCB and the SL-Relay PCB.
3. Replace the SL-Relay PCB with a new one.
(Refer to 3.3.2)
4. Replace the FFC located between the Slider PCB and
the SL-Relay PCB
5. Replace the Print Head with a new one. (Refer to 3.1.1)
6. Replace the Slider PCB with a new one.
(Refer to 6.4.5)
20
ERROR 171
NEW HEAD CONNECT
New Print Head was recognized. It is normal that an error occurs only at the time of the first
start after having connected a new head.
It is abnormal that an error occurs at the time of start every
time..
1. Check connection between the Slider PCB from the
Print Head
2. Replace the Slider PCB with a new one.
(Refer to 6.4.5)
3. Replace the Print Head with a new one. (Refer to
3.1.1)
21
ERROR 172
Main PCB Q6 Check
The main PCB Q6 is disabled (short mode).
(Displayed only at startup in the maintenance
open mode or other than SUPPORT=0.)
1. Replace the Main PCB with a new one. (Refer to 3.3.1)
22
ERROR 201
COMMAND
Command error
Other data than commands is received
1. Check if the output set of the PC matches the set of the
machine side?
2. Change the profile.
3. Check if there is no parameter error?
4. Check if there is no trouble on the USB Cable?
5. Replace the USB Cable.
6. Replace the Main PCB with a new one. (Refer to 3.3.1)
23
ERROR 202
PARAMETER
Parameter error
Parameter out of the numeral value range
is received
24
ERROR 203
Ment Command
Maintenance command
Operation of a maintenance command fails
*Non-disclosed command
Parameter Up/Download and time
setting (LcAeMent [M0xfe])
1. Check the PRM file.
2. Check the number of each parameter.
(if PRM matches up to the machine.)
List of Error Messages (2/9)
No. LCD Cause List of Countermeasures
R.2.0
Maintenance Manual > Troubleshooting > Details on Errors and Malfunctions > List of Error Messages
Model UJF-3042/FX Issued 2010.08.27
Revised
2011.09.30
F/W ver
1.80 / 1.00
Remark
2.0