© 2013 MIMAKI ENGINEERING CO.,LTD.
7.1.4 P.3
7.1.4 List of SYSTEM HALT
1
2
3
4
5
6
7
8
25
SYSTEM HALT (*)
11f : PCB SLIDER
No Slider PCB
.
1. Check the connections between the SL-Relay PCB and
the Slider PCB, and then disconnect and connect the
FFCs or the like.
2. Check the connections between the SL-Relay PCB and
the Main PCB, and then disconnect and connect the
FFCs or the like.
3. Replace the FFCs and the cabeles of the above routes.
4. Replace the Slider PCB with a new one. (Refer to
6.4.5)
5. Replace the SL-Relay PCB with a new one.
(Refer to 3.3.2)
6. Replace the Main PCB with a new one. (Refer to 3.3.1)
26
SYSTEM HALT (*)
10a : HDC INIT
Initialization error of the Slider PCB
(FPGA)
27
SYSTEM HALT (*)
120 : LCD THERM.
LCD thermistor IC RW error 1. Check the connections between the Keyboard PCB and
the Main PCB, and then disconnect and connect the
FFCs.
2. Replace the FFCs and the cabeles of the above routes.
3. Replace the Keyboard PCB with a new one.
4. Replace the Main PCB with a new one. (Refer to 3.3.1)
5. Replace the Power Supply PCB with a new one.
(Refer to 6.4.1)
28
SYSTEM HALT (*)
122 : PRAM NONE
No PRAM 1. Update F/W.
2. Replace the Main PCB with a new one. (Refer to 3.3.1)
29
SYSTEM HALT (*)
123 : PRAM DATA
PRAM data error
30
SYSTEM HALT (*)
124 : PRAM ADDR
PRAM address error
31
SYSTEM HALT (*)
125 : EEPROM READ
EEPROM read trouble 1. Update F/W.
2. Upload the parameter and initialize parameter with
#PARAMETER.
3. Check the connection state between Main PCB ~ SL-
Relay PCB.
4. Replace the Main PCB with a new one. (Refer to 3.3.1)
5. Replace the SL-Relay PCB with a new one.
(Refer to 3.3.2)
32
SYSTEM HALT (*)
126 : EEPROM WR
EEPROM write trouble
33
SYSTEM HALT (*)
127 : POWER OFF
Power OFF detection error (Not to OFF)
Power OFF process is conducted in the
Power ON/OFF control without pushing
down the sub-power SW.
1. Check the connection state between sub-power SW and
Keyboard PCB.
2. Check the connections between the Keyboard PCB and
the Main PCB, and then disconnect and connect the
FFCs.
3. Check the connector connection of Power Supply PCB.
4. Check if there is no error on the power path from the
AC Inlet.
5. Replace the Power Supply PCB with a new one.
(
(Refer to 6.4.1)
)
6. Replace the Keyboard PCB with a new one.
7. Replace the Main PCB with a new one. (Refer to 3.3.1)
8. Replace the Station III PCB with a new one. (Refer to
6.4.4)
9. Replace the SL-Relay PCB with a new one.
(Refer to 3.3.2)
10. Replace the Slider PCB with a new one. (Refer to
6.4.5)
List of SYSTEM HALT (3/7)
No. LCD Cause Corrective Measures
R.2.0
Maintenance Manual > Troubleshooting > Details on Errors and Malfunctions > List of SYSTEM HALT
Model UJF-3042/FX Issued 2010.08.27
Revised
2011.09.30
F/W ver
1.80 / 1.00
Remark
2.0