© 2013 MIMAKI ENGINEERING CO.,LTD.
7.1.4 P.7
7.1.4 List of SYSTEM HALT
1
2
3
4
5
6
7
8
62
SYSTEM HALT (*)
813 : FW/WIPER RN
FW error
(Wiper operation range error)
1. Update F/W.
2. Check and clear the parameter.
3. Disconnect and connect the FFC located between the
Main PCB and the SL-Relay PCB.
4. Disconnect and connect the FFC located between the
Main PCB and the Station III PCB.
5. Disconnect and connect the FFC located between the
SL-Relay PCB and the Slider PCB.
6. Replace the FFC located between the Main PCB and
the SL-Relay PCB.
7. Replace the FFC located between the Main PCB and
the Station III PCB.
8. Replace the FFC located between the SL-Relay PCB
and the Slider PCB.
9. Replace the Main PCB with a new one. (Refer to 3.3.1)
63
SYSTEM HALT (*)
814 : FW/drivinfm
FW error
(drivinfm() information obtaining error
64
SYSTEM HALT (*)
815 : FW/SIO rsrc
FW error
(Serial control F/W error (material control))
65
SYSTEM HALT (*)
816 : FW/FROM WRC
FW error
(FROM write control error)
66
SYSTEM HALT (*)
817 : FW/SaveArea
FW error
(Save area error (size over))
67
SYSTEM HALT (*)
818 : FW/EEP SIZE
FW error
(EEPROM size over)
68
SYSTEM HALT (*)
819 : FW/HROM SIZ
FW error
(HDROM size over)
69
SYSTEM HALT (*)
81a : FW/FROM SIZ
FW error
(FROM size over)
70
SYSTEM HALT (*)
81b : FW/STACK OV
FW error
(STACK OVER)
71
SYSTEM HALT (*)
000 : IOC1/ADC
System error
(STC3 A/D start error)
1. Confirm the neighboring temperature of the Station III
PCB. In addition, confirm whether and it is an error by
the heat reckless driving of FPGA.
2. Confirm whether there is not a device generating
powerful electromagnetic waves to circumference.
3. Replace the Slider PCB with a new one. (Refer to
6.4.5)
4. Replace the Main PCB with a new one. (Refer to 3.3.1)
5. Replace the Power Supply PCB with a new one.
(Refer to 6.4.1)
72
SYSTEM HALT (*)
000 : IOC2/ADC
System error
(SPC A/D start error)
1. Confirm the neighboring temperature of the SL-Relay
PCB. In addition, confirm whether and it is an error by
the heat reckless driving of FPGA.
2. Confirm whether there is not a device generating
powerful electromagnetic waves to circumference.
3. Replace the Slider PCB with a new one. (Refer to
6.4.5)
4. Replace the Main PCB with a new one. (Refer to 3.3.1)
5. Replace the Power Supply PCB with a new one.
(Refer to 6.4.1)
73
SYSTEM HALT (*)
000 : HDC/ADC
System error
(HDC A/D start error)
1. Confirm the neighboring temperature of the Slider
PCB. In addition, confirm whether and it is an error by
the heat reckless driving of FPGA.
2. Confirm whether there is not a device generating
powerful electromagnetic waves to circumference.
3. Replace the Slider PCB with a new one. (Refer to
6.4.5)
4. Replace the Main PCB with a new one. (Refer to 3.3.1)
5. Replace the Power Supply PCB with a new one.
(Refer to 6.4.1)
74
SYSTEM HALT (*)
000 : UNNOWN ERR
Unnown error 1. Update F/W.
2. Check and clear the parameter.
3. Replace the Main PCB with a new one. (Refer to 3.3.1)
List of SYSTEM HALT (7/7)
No. LCD Cause Corrective Measures
R.2.0
Maintenance Manual > Troubleshooting > Details on Errors and Malfunctions > List of SYSTEM HALT