© 2011 MIMAKI ENGINEERING CO.,LTD. 2.3.4 R.2.0 P.2
2.3.4 3042 Station3 PCB Assy.
1
2
3
4
5
6
7
8
* For the details of connecting destinations, refer to the block dia-
gram.
Test poi nt
LED Specification
Fuse Specification
Power supply confirmation point
CN20 2 Not Use Connector is not mounted.
CN21 8 Not Use Connector is not mounted.
CN22 10 Not Use Connector is not mounted.
CN23 16 Not Use Connector is not mounted.
Parts No. Pin Connected to:* Connecting
destination CN
Remarks
Parts No. Signal Remarks
TP1-4 GND
Parts No.
, Signal Remarks
D1 Fuse check of F1. If the fuse blown out, it is turned off.
D9 Sensor check of CN15 No. 2 Pin (Z origin sensor)
D10 Sensor check of CN15 No. 5 Pin (not being used)
D11 Sensor check of CN15 No. 8 Pin (not being used)
D12 Sensor check of CN15 No. 11Pin (not being used)
Parts No.
, Rate Using Voltage Remark
F1 3.15A AC125V, DC60V +35V CN3
Confirmation point DC Power Voltage Remarks
Parts No. Pin No.
EC1 [+] Pin +35V
EC2 [+] Pin +5VU +5V
EC12 [+] Pin +13V - +25.2V For FAN output (variable)
IC11 6Pin +5V
IC11 1Pin +3.3V
IC12 1Pin +1.5
Maintenance Manual > Electrical Parts > Circuit Board Specifications > 3042 Station3 PCB Assy.
Model UJF-3042/FX Issued 2010.08.27 Revised 2011.09.30 F/W ver 1.80 / 1.00 Remark
2.0