4.7.4.1 Parameters
In this menu item, the parameters of the weighing electronics for A+B scale are
congured.
Accessible via MENU - [Operating] - [System setup]- [Weighing points]- [Weighing
point x]- [Parameters] .
WP-C
Max 6000kg d= 1kg
617
+
kg
Weighing points @admin
Weighing point A
Weighing point B
Weighing point C
Weighing point D
Internal weighing point
Internal weighing point
A+B
SBI scale
Parameters
WP-C
Max 6000kg d= 1kg
617
+
kg
Weighing points @admin
Weighing point C
Settings locked
W&M
A+B
none
Default Save
[Settings locked]
The weighing point settings and assignment can only be viewed as if the
corresponding CAL switch were closed; see Chapter 2.7.1.
[W&M]
Setting for operation in legal metrology.
Selection: [None], OIML, NTEP (for USA) or NSC (for Australia), see Chapter 4.7.1.1.1.
[Default] soft key
Settings are reset to factory settings.
1. In this case: Select [Weighing point C] with [A+B] and press the [Parameters] soft key.
A selection window opens.
2. Select and conrm the individual parameters.
3. Press the [Save] soft key to save the settings.
4 System setup Process Controller Maxxis 5 PR 5900
EN-131 Minebea Intec