EasyManua.ls Logo

Minebea Intec PR5900 - Page 100

Default Icon
382 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setting range: 0…9999999 d
For use in legal metrology a value of max. 9 d = e must be set.
[Min. weight]
Minimum weight at which a print command can be triggered.
Setting range: 0…9999999 d
For use in legal metrology a value of at least 20 d must be set.
[Range mode]
Selection: single range, multi-range, multi-interval
For range selection for scales and settings, refer to Chapter 4.7.1.1.2 and 4.7.1.1.3
[Default] soft key
Settings are reset to factory settings.
4.7.1.1.1 W&M (use in legal metrology)
In this menu item (under Parameters), the parameters of the Internal weighing point
weighing electronics are congured for use in legal metrology.
Accessible via MENU - [Operating] - [System setup] - [Weighing points] - [Weighing
point x] - [Parameters] - [W&M] .
The following parameters can be selected: [None], OIML, NTEP (for USA) or NSC (for
Australia)
[None] [OIML] [NTEP] [NSC]
Gross weight display B B G G
0.2 mV/V @
30,000 d
0.2 mV/V @
3000 e
0.2 mV/V @
3000 e
0.2 mV/V @
3000 e
Recommended
min. measurement sig-
nals
0.4 mV/V @
60,000 d
0.4 mV/V @
6000 e
0.4 mV/V @
6000 e
0.4 mV/V @
6000 e
If legal-for-trade mode is switched on, the parameter settings (zerotrack etc.) must be
selected accordingly. The device does not perform a check of this.
A unique check number is created every time a calibration or changed parameters are
saved. This can be viewed in the menu [Operating] - [System information] - [Show
calibration check numbers] (see Chapter 5.7) and may also be written on the W&M label.
See also Chapter 4.7.1.2.
4.7.1.1.2 Range mode: Multi-range
In this menu item (under Parameters), a multi-range scale (of Class III or single-range
scale of Class I and II with variable scale interval) of the Internal weighing point weighing
electronics is congured
The multi-range scale is a scale with two or more weighing ranges with dierent
maximum capacities and scale intervals. There is only one load receptor, with each range
covering zero to its maximum capacity.
When [Range mode] = [Multi-range], the scale has up to three ranges with dierent
resolution.
3. Press the [Save] soft key to save the settings.
Process Controller Maxxis 5 PR 5900 4 System setup
Minebea Intec EN-98

Table of Contents