WP-C
R1 Max 29.9kg d= 0.0005kg
00000
+
kg
xBPI weighing parameters @admin
Ambient conditions
Application/Filter
Standstill time
Stability symbol delay
Tare parameters
Auto zero function
very stable condition
Standard mode
0.25 digit
No delay
At any time
Auto Zero on
Save
Note:
Only the parameters supported by the connected scale are displayed.
[Ambient conditions]
Selection: very stable condition, Stable condition, Unstable condition, Very unstable
condition
[Application/Filter]
Selection: Standard Mode, manual lling, automatic dosing, Checkweighing
[Standstill range]
Selection: 0.25 digit, 0.5 digit, 1 digits, 2 digits, 4 digits, 8 digits
[Stability symbol delay]
Selection: No delay, Short delay, Average delay, Long delay
[Tare parameters]
Selection: At any time, Not until stable
[Auto zero function]
Selection: on, o
[Adjustment function]
Selection: Ext.adj.w.fact.wt., Ext.adj.w.user wt., Ext.adj.w.pres.wt., Internal adjust,
Ext.lin.w.fact.wt., Ext.lin.w.user wt., Conrm preload/dead load, Delete preload/dead
load, Adjust disabled
[Conrming adjustment]
Selection: automatically, manual
[Zero range]
Selection: 1 % of max. load, 2 % of max. load, 5 % of max. load, 10 % of max. load