Weighing point C @admin
Weighing point
Interface
Baudrate
Data bits
Parity
Stop bits
Mettler-Scale
Built-in RS-232
9600 baud
7 data bits
odd parity
1 stop bit
Default Save
Inactive parameters are grayed out.
[Interface]
Serial interfaces.
Selection: not assigned, Built-in RS-232, Built-in RS-485,Option‑x RS-485‑A,
Option‑x RS-485‑B
[Baud rate]
Baud rate of the data transfer.
Note:
The selected value must match the value of the connected device.
Selection: 300, 600, 1200, 2400, 4800, [9600], 19200 baud
[Parity]
Parity check for detecting errors during data transmission.
Selection: no parity, odd parity, even parity
[Default] soft key
Settings are reset to factory settings.
4.7.10.2 Parameters
In this menu item, the parameters of the Mettler-Scale weighing electronics are
congured.
Accessible via MENU - [Operating] - [System setup] - [Weighing points] - [Weighing
point x] - [Parameters] .
2. Select and conrm the individual parameters.
3. Press the [Save] soft key to save the settings.