Printer @admin
Interface
Protocol
Baudrate
Data bits
Parity
Stop bits
Printer type
Built-in RS-232
XON/XOFF
9600 baud
8 data bits
no parity
1 stop bit
EPSON TM-U220
Default Test print Save
[Protocol]
Transmission protocol
Selection: no protocol, XON/XOFF, RTS/CTS
[Baud rate]
Baud rate of the data transfer.
Selection: 300, 600, 1200, 2400, 4800, [9600], 19200, 38400, 57600, 115200 baud
Note:
The selected value must match the value of the connected device.
[Data bits]
Groups of data bits.
Selection: 7 data bits, [8 data bits]
[Stop bits]
Units for transmission protocols.
Selection: 1 stop bit, [2 stop bits]
[Printer type]
The printer type depends on the printer: raw, CR/LF translation, EPSON TMU220,
EPSON LQ-300K, Generic PCL5 (Unicode), Generic PCL5 (codepage), Generic ESC/P2
4.1.4.2 Network printer
In this menu item (under Printer), the parameters for a network printer are congured.
Accessible via MENU - [Operating]- [System setup]- [Connected devices]- [Printer]-
[Interface]- [Network printer] .
2. Select and conrm the individual parameters.
3. Press the [Test print] soft key.
A test page (see Chapter 10.2) is printed.
4. Check the printer settings and change if necessary.
5. Press the [Save] soft key to save the settings.