Chapter 3: AT Commands Reference
December 31, 2007 AT Commands Reference Manual 3-225
// report originated by G24
// Converter num=1, report=3, rate=5*100ms, low,high, N_samples,
duration=5
AT+MMAD =1,3,5, , ,16,5,30
OK
+MMAD:1,175 //First report
+MMAD:1,140 //Second report
…..
+MMAD:1,160 //Last Avr report
AT+MMAD =1,0,5, , ,16,5,0 // Activate Average calculation during 5 minutes, rate=5.
// Converter num=1, report=0, rate=5*100ms, low,high, 16,
duration=5 min
OK
AT+MMAD=1 //Only on explicit "AT+MMAD=<Converter_number>" command
Ok
+MMAD:1,160
//Operation not allowed because the parameters are valid But the
there is not enough time for calculation:
AT+MMAD =1,3,100, , ,7,1,5 // Activate Average calculation during 1 minute, rate=100,
samples = 7, report interval = 5 sec.
Converter num=1, report=3, rate=100, low,high, 7,
duration=1 min, interval = 5.
+CME ERROR: operation not allowed
AT+MMAD =1,0 // Stop Average calculation and report.
OK //Converter num=1, report=0
AT+MMAD? // Read monitoring setup values of all A2D's
+MMAD:1,0,10,0,230,0,0,0
+MMAD:2,1,15,0,230,0,0,0
+MMAD:3,2,1,25,100,0,0,0
+MMAD:4,0,1,0,255,0,0,0
+MMAD:5,0,1,300,450,0,0,0
OK
AT+MMAD? // Read default values of all A2D's
+MMAD: 1,0,1,0,230,0,0,0
+MMAD: 2,0,1,0,230,0,0,0
+MMAD: 3,0,1,0,230,0,0,0
+MMAD: 4,0,1,0,255,0,0,0
+MMAD: 5,0,1,300,450,0,0,0
OK
AT+MMAD=? //Test command - range of all setup parameters and
+MMAD: (1-5),(0-3),(1-255),(0-450),(0-450),(2-255),(1-255),(0-255)