Chapter 3: AT Commands Reference
December 31, 2007 AT Commands Reference Manual 3-425
+FTS, Transmit Silence
This command causes the G24 to stop any transmission. The G24 then waits for the specified
amount of time, and sends the OK result code to the terminal.
The following table shows the +FTS parameters.
Example
At+fclass=1
OK
Atd035658584
CONNECT 9600
OK
AT+FTS=20
OK
+FRS, Receive Silence
This command causes the G24 to wait for silence and to report back an OK result code when
silence has been present on the line for the specified amount of time. The command terminates
when the required amount of silence on the line is detected or when the terminal sends the G24 a
character other than <DC1> (11h) or <DC3> (13h), which is discarded. In either event, the OK
result code is returned to the terminal.
Command Type Syntax Response/Action Remarks
Set
AT+FTS =
<Time>
OK
or:
+CME ERROR: <err>
The Set command causes the terminal
to stop any transmission.
Table 3-282: +FTS Parameters
<Parameter> Description
<Time> The time the terminal waits, in 10 millisecond intervals
0-255 Number of milliseconds
Command Type Syntax Response/Action Remarks
Set
+FRS = <Time> OK
or:
+CME ERROR: <err>
The Set command specifies the
amount of time the line must be silent.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola G24 Guide and is the answer not in the manual?

Motorola G24 Guide Specifications

General IconGeneral
BrandMotorola
ModelG24 Guide
CategoryTelephone Accessories
LanguageEnglish

Related product manuals