GPRS/EDGE
3-414 AT Commands Reference Manual December 31, 2007
OK
AT+MSDNS?
+MSDNS: 1,"192.118.9.177","192.118.11.77"
+MSDNS: 2,"192.118.9.177","192.118.11.77"
+MSDNS: 3,"192.118.9.177","192.118.11.77"
+MSDNS: 4,"192.118.9.177","192.118.11.77"
+MSDNS: 5,"192.118.9.177","192.118.11.77"
OK
AT+MIPCALL=0
OK
NO CARRIER
+MIPCALL: 0
AT+MSDNS? // read when MIPCALL is disconnected
+MSDNS: 1,"0.0.0.0","0.0.0.0"
+MSDNS: 2,"0.0.0.0","0.0.0.0"
+MSDNS: 3,"0.0.0.0","0.0.0.0"
+MSDNS: 4,"0.0.0.0","0.0.0.0"
+MSDNS: 5,"0.0.0.0","0.0.0.0"
OK
+MIPCSC, Motorola Control Secured Connection
This AT command is used to configure the SSL feature behavior in case of non - fatal alerts. For
each non - fatal alert, user should decide if the secure connection should be closed automatically
or not.
Command Type Syntax Response/Action Remarks
Set
AT+MIPCSC=<SocketID>,<n> OK
or:
+CME ERROR: <err>
The Set
command is used
for setting the
SSL connection
behavior in case
of non - fatal
alerts.
Read
AT+MIPCSC? + MIPCSC: 1,<n>
+ MIPCSC: 2,<n>
+ MIPCSC: 3,<n>
+ MIPCSC: 4,<n>
OK
The Read
command
returns the
current SSL
connection
behavior in case
of non - fatal
alerts.
Test
AT+MIPCSC=? + MIPCSC:
(1-4),(0- 2047)
OK
The Test
command
returns the
possible range of
values.

Table of Contents