CALL INFORMATION SYSTEM (CIS)
PROGRAMMING
TIMS Printer Programming
– 123 –
A2107-10
DESCRIPTION DATA
Specify the symbol of the currency printed
out.
(1)
(2)
256
0 : $
1 : Not printed
( will be printed)
2 : FF
Specify the number to be deleted from
called party number in call record printout.
(1)
(2)
2
0 : All digits are printed
1-25: Last 1-25 digits are deleted
26 : All digits are deleted
Specify the printing pattern in which the
hotel name (company name) is printed at
the end of the billing information.
(1)
(2)
3
0 -7: See the following table.
Specify the number of line feeds after
printing.
(1)
(2)
6
0 : No line feed
1-10: 1-10 line feeds
Specify the call duration by which the long-
time call record is printed out.
(1)
(2)
10
0 : No printing
1-225: Print every 1-255 minutes
Specify the maximum number of Immedi-
ate Printout Call Record for the Printer
which is set to “17” by CMD001>100/140.
(1)
(2)
23
1-1000 : 1 call-1000 calls
CMD001
D
CMD003
X: print
–: Not print
2nd Data
Station Individual
Totaled Bill Print
Station Individual
Call Record Print
Call Record
Immediate Print
0
1 X
2 X
3 X X
4 X
5 X X
6 X X
7 X X X