CALL INFORMATION SYSTEM (CIS)
PROGRAMMING
TIMS Printer Programming
– 124 –
A2107-10
DESCRIPTION DATA
Specify the maximum number of call
record for D
term
TIMS.
(1)
(2)
28
0 : Not used
1-12000: 1 call-12000 calls
Specify the maximum number of waiting
buffer for the Immediate Printout Call
Record for the Printer which is set to “16”
by CMD001>100/140.
(1)
(2)
30
0 : Not used
1-1000: 1 call-1000 calls
Clear the billing memory.
NOTE: Before executing CMD102, be
sure to print out all of the stored
call records.
CMD102 deletes all of the stored
call records.
(1)
(2)
0000
CCC
Specify when the external equipment is
started depending on the number of the
remaining AP memory blocks.
(1)
(2)
27
0 : External Alarm is not executed
1-27000: 1 block-27000 blocks
Specify the threshold for the automatic
printout of the call record accumulation
overflow.
(1)
(2)
31
0 : Printout is not executed
1-12000: 1 call-12000 calls
Assign the time and day for daily/monthly
report with the Printer, if required.
(1)
(2)
21-28
XXXX: Time and Day
When you provide the external alarm indi-
cation through the DK, specify the external
equipment starting condition when the call
record has reached the value specified by
CMD003>23, 27, 28, 30.
(1)
(2)
XX Y
XX: 00-31: DK Card No. assigned by
CM10 (E800-E831)
Y : 0-3: Circuit No.
313: MP built-in External Equipment In-
terface
3000: When the call record has
reached the value specified by
CMD003>28
3003: When the call record has
reached the value specified by
CMD003>23 or 30
3004: When the call record has
reached the value specified by
CMD003>27
CMD003
CMD004
CM44
CMD102
E
CMD003
AP OFF LINE