DIRECT INWARD DIALLING (DID)
– 223 –
A2222-10
DESCRIPTION DATA
(1)
(2)
Y=05 Release Signal Condition
00-63: Trunk Route No.
1 : Release Signal arrives
(1)
(2)
Y=09 Incoming Connection Signaling
00-63: Trunk Route No.
06: 2nd DT/Timing Start
(1)
(2)
Y=12 Number of digits to be received
00-63: Trunk Route No.
Number of digits
0 : 1 digit
1 : 2 digits
2 : 3 digits
3 : 4 digits
(1)
(2)
Y=18 Received Digit Conversion
00-63: Trunk Route No.
0 : To provide
1 : Not provided
(1)
(2)
Y=59 Call Waiting for DID call
00-63: Trunk Route No.
0 : To provide
1 : Not provided
NOTE: When 2nd data is set to “1”, the
Trunk ID number assigned by
CM30 Y=19 is displayed.
(1)
(2)
Y=75 DID incoming LDN Display on
D
term
/ATTCON/DESKCON
00-63: Trunk Route No.
0 : Available
1 : Not available
NOTE
(1)
(2)
Y=78 Digit conversion of leading 2-4
digits of DID incoming LDN
00-63: Trunk Route No.
0 : Available
1 : Not available (All digits of DID in-
coming LDN are converted by
CM76.)
CM35
A
B

Table of Contents

Other manuals for NEC NEAX 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC NEAX 2000 and is the answer not in the manual?

NEC NEAX 2000 Specifications

General IconGeneral
BrandNEC
ModelNEAX 2000
CategoryServer
LanguageEnglish

Related product manuals