DISTINCTIVE RINGING
– 240 –
A2234-10
DESCRIPTION DATA
NOTE 1: • When immediate ringing is sent from the Main PBX (Centrex), CM41 Y=2>40
plus CM41 Y=2>41 must be assigned as longer time than the time assigned by
CM41Y=2>00.
• When immediate ringing is not sent from the Main PBX (Centrex), CM41
Y=2>40 must be assigned as longer time than the time assigned by CM41
Y=2>40.
• Check the Main PBX (Centrex) ringer cycle and set as shown below:
NOTE 2: When Immediate Ringing is not provided on Main PBX, be sure to set CM41
Y=2>41 as 00.
Assign the Trunk Line Appearance key to a
D
term
.
•
(1)
(2)
Y=00
My Line No. + + Key No.
D000-D255: Trunk No.
Provide the tone ringer on call termination.
NOTE: When CM30 Y=02/03 2nd data is
03, this setting is required.
•
(1)
(2)
Y=01
My Line No. + + Key No.
0 : Disabled
1 : Enabled
CM41
CM90
END
A sec.
B sec.
Main PBX Ringing
(Station termination)
Main PBX Ringing
(C.O. termination)
When the gap between the Main PBX station terminating ringer and C.O. line
terminating ringer is under 200 ms, distinction may be incomplete.
B sec. < CM41 Y=2>40 setting time < A sec.
,
,
C