EasyManua.ls Logo

NEC NEAX 2000 - Page 259

NEC NEAX 2000
1200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DISTINCTIVE RINGING
– 239 –
A2234-10
DESCRIPTION DATA
Provide the distinctive ringing patterns to a
D
term
in behind PBX.
(1)
(2)
Y=87
00-63: Trunk Route No.
0 : To provide
1 : Not provided
Specify the terminating system for incom-
ing C.O. calls.
(1)
(2)
Y=02 in Day Mode
Y=03 in Night Mode
Y=40 in Mode A
Y=41 in Mode B
000-255: Trunk No.
02: Trunk Line Appearance
03: Trunk Line Appearance + TAS
Provide the Trunk Line Appearance-D
term
.
(1)
(2)
Y=18
000-255: Trunk No.
0 : To provide
1 : Not provided
Assign the ringing detect timer for incom-
ing trunk calls.
(1)
(2)
Y=2
00
06-10: 192 ms.-320 ms.
(32 ms. increments)
If no data is set, the default setting is 256-
288 ms.
Assign the Main PBX (Centrex) ringing
distinction timer.
NOTE 1 on next page
(1)
(2)
Y=2
40
01-15: 128 ms.-1920 ms.
(128 ms. increments)
If no data is set, the default setting is 1280-
1408 ms.
Assign the immediate ringing guard timer
from the Main PBX (Centrex).
NOTE 1, NOTE 2 on next page
(1)
(2)
Y=2
41
00-99: 0 ms.-12672 ms.
(128 ms. increments)
If no data is set, the default setting is 384-
512 ms.
CM35
C
CM41
B
CM30

Table of Contents