DISTINCTIVE RINGING
– 239 –
A2234-10
DESCRIPTION DATA
Provide the distinctive ringing patterns to a
D
term
in behind PBX.
•
(1)
(2)
Y=87
00-63: Trunk Route No.
0 : To provide
1 : Not provided
Specify the terminating system for incom-
ing C.O. calls.
•
•
•
•
(1)
(2)
Y=02 in Day Mode
Y=03 in Night Mode
Y=40 in Mode A
Y=41 in Mode B
000-255: Trunk No.
02: Trunk Line Appearance
03: Trunk Line Appearance + TAS
Provide the Trunk Line Appearance-D
term
. •
(1)
(2)
Y=18
000-255: Trunk No.
0 : To provide
1 : Not provided
Assign the ringing detect timer for incom-
ing trunk calls.
•
(1)
(2)
Y=2
00
06-10: 192 ms.-320 ms.
(32 ms. increments)
If no data is set, the default setting is 256-
288 ms.
Assign the Main PBX (Centrex) ringing
distinction timer.
NOTE 1 on next page
•
(1)
(2)
Y=2
40
01-15: 128 ms.-1920 ms.
(128 ms. increments)
If no data is set, the default setting is 1280-
1408 ms.
Assign the immediate ringing guard timer
from the Main PBX (Centrex).
NOTE 1, NOTE 2 on next page
•
(1)
(2)
Y=2
41
00-99: 0 ms.-12672 ms.
(128 ms. increments)
If no data is set, the default setting is 384-
512 ms.
CM35
C
CM41
B
CM30