ā 330 ā
A2325-10
MESSAGE CENTER INTERFACE (MCI)
PROGRAMMING
MCI Programming
DESCRIPTION DATA
Assign the attribute data, depending on
the port (Port 0-3) connected to the VMS.
(1)
(2)
See the following table.
See the following table.
NOTE 1: For the Port 1 and Port 3, data speed 9600 bps can not be set.
NOTE 2: This data should be assigned depending on the attribute of VMS.
NOTE 3: To send the text to the VMS successively, assign the guard timer.
CMD001
B
C
AP00 INITIAL
FIRST DATA (1)
MEANING
SECOND
DATA (2)
MEANING
PORT
0
PORT
1
PORT
2
PORT
3
20 24 28 32 Data speed 2/3/4/5
NOTE 1
1200/2400/4800/9600
bps NOTE 2
21 25 29 33 Stop bit length 0 /1/2 1/1.5/2 bits NOTE 2
22 26 30 34 Data length 0 /1 7/8 bits NOTE 2
23 27 31 35 Parity 0 /1/2 None Parity/Even Par-
ity/Odd Parity NOTE 2
80 100 120 140 Equipment Type 24 MCI
81 101 121 141 Priority for data processing 0 1st Priority
85 105 125 145 Station Address (SA) 48 0
86 106 126 146 Unit Address (UA) 33 !
89 109 129 149 Timer for detecting the end of block 5 512 msec.
98 118 138 158 Guard timer between texts 0
1
2
3
4
0~128
128~256
256~384
384~512
512~640
NOTE 3