ANALOG PORT ADAPTER-D
term
– 19 –
A2018-10
To assign the Dual Port Mode:
(1) Data Assignment for D
term
accommodates the Analog Port Adapter
(2) Data Assignment for Analog Terminal connected to the Analog Port Adapter
DESCRIPTION DATA
Provide the Analog Port Adapter to the re-
quired stations.
•
(1)
(2)
Y=32
X-XXXXXXXX: My Line No.
0: To connect
Assign the Dual Port Mode to the required
stations.
•
(1)
(2)
Y=33
X-XXXXXXXX: My Line No.
0: Dual Port Mode
DESCRIPTION DATA
Assign an analog terminal station number
to the required LEN.
(1)
(2)
000-763: LEN
FX-FXXXXXXXX: Analog Terminal
Station No.
NOTE: The analog terminal station number must be assigned to the following LEN.
Analog Terminal LEN=D
term
LEN + 8
For example, when the DLC card is mounted on LT01 slot;
For D
term
LEN: 008-015
For Analog Terminal LEN: 016-023*
* LT02 slot must be vacant.
START
CM13
END
INITIAL
START
CM10
A