ANNOUNCEMENT SERVICE
– 23 –
A2018-10
NOTE 1: A maximum of five different announcements can be accessed. There is a limit of 10
Digital Announcement Trunk Circuit for each of the five different announcements.
When recording an announcement, each Digital Announcement Trunk Circuit must be
recorded individually.
NOTE 2: Each time a station is connected to a Digital Announcement Trunk Circuit, the message
will be repeated three times. The station will then be disconnected.
NOTE 3: For the single connection of a Digital Announcement Trunk Circuit, the duration of an
announcement is limited to 120 seconds.
NOTE 4: For the multi-connection of a Digital Announcement Trunk Circuit, the duration of re-
play for an announcement is programmable from 4 to 396 seconds.
DESCRIPTION DATA
When Multiple Connections is provided
(CM08>124: 0), specify the duration of
message replay for the Announcement
Service.
(1)
(2)
Y=0
53
01-99: 4 sec.-396 sec.
(4 sec. increments)
If no data is set, the default setting is
60-64 sec.
Assign the function for each Digital An-
nouncement Trunk card.
(1)
(2)
Y=00
000-001: Built-in DAT on MP card
002-127: Digital Announcement Trunk
Card No. (EB002-EB127) as-
signed by CM10
04X Z
X: 0-4: Group No.
Z: 0-9: Message No.
To provide a C.O./Tie Line party with this
service, assign the Announcement Ser-
vice Group 0-4 to the required trunk
routes.
(1)
(2)
Y=69 Announcement Service Group 0
Y=70 Announcement Service Group 1
Y=71 Announcement Service Group 2
Y=72 Announcement Service Group 3
Y=73 Announcement Service Group 4
00-63: Trunk Route No.
1 : Allow
CM35
END
CM41
B
CM49