ANNOUNCEMENT SERVICE
– 25 –
A2018-10
NOTE: Announcement Service can be used to provide a voice message when an incoming
C.O. line/Tie line call has been transferred and encounters a busy or no answer condi-
tion. After the voice message is given, normal call processing continues.
This application can be programmed on a tenant basis.
Only one (1) message of up to the following seconds can be recorded on an individ-
ual Digital Announcement Trunk Card.
Built-in DAT on MP: 120 sec.
4DAT card: 120 sec.
In this application, a minimum of two Digital Announcement Trunk Circuits are need-
ed, one for busy condition, and one for no answer.
More than one Digital Announcement Trunk Circuit can be used, depending on traffic
conditions.
System programming can be set to, wait until circuit(s) become free or immediately
follow preprogrammed normal call handling, if a busy condition is encountered.
Digital Announcement Trunk Circuits can be shared among tenants.
This feature does not function on Attendant transferred calls.
DESCRIPTION DATA
Assign the function for each Digital An-
nouncement Trunk card.
(1)
(2)
Y=00
000-001: Built-in DAT on MP card
002-127: Digital Announcement Trunk
Card No. (EB002-EB127) as-
signed by CM10
06XX: No Answer
XX : 00-63: Message No.
07XX: Busy
XX : 00-63: Message No.
(1)
(2)
Y=06 No Answer
Y=07 Busy
XX: 00-63: Tenant No. of transferring
station
XX: 00-63: Message No. assigned by
Y=00
To record, replay and delete a message,
assign the respective Digital Announce-
ment Trunk access code.
(1)
(2)
Y=0-3 Number Plan Group 0-3
X-XXXX: Access Code
A100: Record
A101: Replay
A102: Delete
CM20
END
CM49
A