Loading...
SPEED CALLING-SYSTEM
SPEED CALLING-SYSTEM-D
term
– 455 –
A2452-10
To use the 1000-Slot Memory Block number (0-3) for Speed Calling-Station as the Memory Block
for Speed Calling-System, add the following programming.
DESCRIPTION DATA
Specify the 1000-Slot Memory Block num-
ber 0-3.
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)
112: 1000-Slot Memory Block No. 0
0 : Available
1 : Not available
111: 1000-Slot Memory Block No. 1
0 : Available
1 : Not available
176: 1000-Slot Memory Block No. 2
0 : Available
1 : Not available
110: 1000-Slot Memory Block No. 3
0 : Available
1 : Not available
Assign the Access Code for Speed Call-
ing-System.
(1)
(2)
Y=0-3 Numbering Plan Group 0-3
X-XXXX: Access Code
A152: 1000-Slot Memory Block No. 0
A151: 1000-Slot Memory Block No. 1
A068: 1000-Slot Memory Block No. 2
A150: 1000-Slot Memory Block No. 3
Assign the stored number to each Memory
Slot number.
(1)
(2)
Y=0
X YY Z
X : 0-3 (Basic), 4-9 (Option): 1000-Slot
Memory Block No.
YY: 00-99: 10-Slot Memory Block No.
Z : 0-9: Memory Parcel No.
Stored No.:
Outgoing Call Access Code (Max.
4 digits) + + Called Party’s No.
(Max. 26 digits)
To set a pause into the stored No., enter “C”
(Fixed Pause=1.5 sec.) or “D” (Programma-
ble Pause specified by CM41 Y=0>38) after
desired digits.
CM20
CM74
START
CM08
A