SPLIT CALL FORWARDING-DON’T ANSWER
– 464 –
A2463-10
DESCRIPTION DATA
Assign the access code for Split Call For-
warding-Don’t Answer.
(1)
(2)
X-XXXX: Access Code
A182: Split Call Forwarding-Busy Line/
-Don’t Answer Entry
A183: Split Call Forwarding-Busy Line/
-Don’t Answer Cancel
To apply this feature to incoming calls, as-
sign the combination of trunk routes for
Tandem Connection.
(1)
(2)
Y=05
00-63: Trunk Route No.
1 : Release Signal arrives
(1)
(2)
Y=0
Incoming Trunk Route No. + Outgoing
Trunk Route No. assigned by CM35
Y=05
0: Allow
Specify the timing for Call Forwarding-
Don’t Answer for a trunk incoming call.
(1)
(2)
Y=0
01
01-30: 4 sec.-120 sec.
(4 sec. increments)
If no data is set, the default setting is 32-36
sec.
Specify the timing for Call Forwarding-
Don’t Answer for an internal call or an as-
sisted call.
(1)
(2)
Y=0
15
01-30: 4 sec.-120 sec.
(4 sec. increments)
If no data is set, the default setting is 32-36
sec.
Specify the setting method for Call For-
warding-Don’t Answer-Outside.
(1)
(2)
222
0 : The feature is set when the station
goes on hook/when receiving Ser-
vice Set Tone (ORT time out)
1 : The feature is set when receiving
Service Set Tone (ORT time out)
Assign whether or not an extension can
set Split Call Forwarding-Don’t Answer-
Outside by entering only a trunk access
code.
(1)
(2)
386
0 : Restricted
1 : Allow
CM41
CM20
A
CM08
CM36
CM35
B

Table of Contents