SPLIT CALL FORWARDING-DON’T ANSWER
– 465 –
A2463-10
DESCRIPTION DATA
Assign whether or not the system should
check the trunk restriction class of the for-
warded station during a Split Call Forward-
ing-Don’t Answer-Outside.
(1)
(2)
387
0 : Follow trunk restriction class
1 : No check
Assign Call Forwarding-Don’t Answer keys
to the D
term
s, as required.
(1)
(2)
Y=00
My Line No. + + Key No.
F0016: Call Forwarding-Don’t Answer
Set/Cancel
For setting the same key as Call Forward-
ing-Busy Line.
(2) F0012: Set/Cancel
Assign Split Call Forwarding-Don’t Answer
keys to the D
term
s, as required.
(1)
(2)
My Line No. + + Key No.
F0A82: Split Call Forwarding-Busy
Line/-Don’t Answer Set/Cancel
Select the feature available in each tenant
when an internal call and a Tie Line/C.O.
incoming call is terminated.
(1)
(2)
Y=23
Internal Call or ATT assisted Call
Y=24 C.O. Incoming Call
Y=25 Tie Line Incoming Call
00-63: Tenant No.
0 : Split Call Forwarding
1 : Call Forwarding
Assign the destination of Split Call For-
warding.
NOTE
(1)
(2)
XX Y
XX: 00-63: Tenant No.
Y : 0-7: Block No.
X-XX + + YY···Y
X-XX : Trunk Access Code
(1-2 digits)
YY···Y: Called No. (Max. 26 digits)
X-XXXXXXXX: Station No. (1-8 digits)
END